8-78 Card replacement procedure
NT2X90
RMM
(continued)
4
At the RMM shelf
5
297–8351–550 Standard 04.01 August 1999
Busy the RMM by typing
>BSY
and pressing the Enter key.
Example of a MAP display:
CM
MS
IOD
.
.
.
RMM
SysB
0 Quit
PM
2 Post_
RMM
3
4
RMM
5
5 Trnsl
6 Tst
7 Bsy
8 RTS
9 OffL
10 LoadPM
11 Disp_
12 Next
13
14 QueryPM
15
16
17
18
CAUTION
Static discharge may cause damage to circuit packs
Put on a wrist strap and connect it to the frame of the
RMM before removing or inserting any cards. This
protects the RMM against service degradation caused
by static electricity.
Replace the NT2X90 card using the procedure "Replacing a card". When you
have completed the procedure, return to this point.
Net
PM
CCS
.
4SysB
.
ManB
OffL
4
0
10
0
1
1
ManB
LNS
Trks
Ext
.
.
.
CBsy
ISTb
3
3
0
0
APPL
.
InSv
130
2