Nortel DMS-100 Series Maintenance Manual page 474

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

8-156 Card replacement procedures
NT6X52
RLCM
(continued)
23
24
25
26
27
297–8351–550 Standard 04.01 August 1999
List the SLM file names into your user directory by typing
>LF volume_name
and pressing the Enter key.
where
volume_name is the name of the volume that contains the PM load files,
obtained in step 20
Leave the disk utility by typing
>QUIT
and pressing the Enter key.
Reload the LCM unit by typing
>LOADPM UNIT lcm_unit CC
and pressing the Enter key.
where
lcm_unit
is the LCM unit to be loaded (0 or 1)
If
load failed
load passed
Return the LCM unit to service by typing
>RTS UNIT lcm_unit
and pressing the Enter key.
where
lcm_unit
is the LCM busied in step 4 (0 or 1)
If RTS
passed
failed
Send any faulty cards for repair according to local procedure.
Do
step 29
step 26
Do
step 27
step 29