If required, align ringing generator activity to the preferred RG by typing
>SWRG UNIT unit_no
and pressing the Enter key.
where
lcm_unit
is the LCM unit (0 or 1)
Note: Repeat this step until both units of the LCM are aligned to the preferred
RG.
If the SWRG command
passed
failed
21
Send any faulty cards for repair according to local procedure.
22
Record the following items in office records:
date the card was replaced
serial number of the card
symptoms that prompted replacement of the card
Go to step 24.
23
Obtain further assistance in replacing this card by contacting personnel
responsible for a higher level of support.
24
You have successfully completed this procedure. Return to the maintenance
procedure that directed you to this card replacement procedure and continue as
directed.
DMS-100 Family RLCM Maintenance Manual XPM12 and up
Card replacement procedures 8-185