Nortel DMS-100 Series Maintenance Manual page 287

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

14
To RTS the busied link, type
>RTS LINK link_no
and press the Enter key.
where
link_no
is the number of a P-side link that has defects busied in step 12
If RTS
passes and other links are not
system busy (SysB)
passes and other links are SysB
fails
15
To display P-side links, type
>TRNSL P
and press the Enter key.
Example of a MAP response:
Link
0: RMM 0
Link
1: RMM 0
Link
2: ESA 0
Link
3: ESA 0
16
To post the remote maintenance module (RMM) or emergency stand-along
(ESA) processor that has defects (if equipped), type
>POST module module_no
and press the Enter key.
where
module
is the name of the P-side module (RMM or ESA)
module_no
is the number of the RMM or ESA processor
17
To busy the RMM or ESA processor, type
>BSY
and press the Enter key.
RLCM alarm clearing procedures 7-103
0;Cap MS;Status:PBsy ,P;MsgCond:CLS
1;Cap MS;Status:PBsy ,P;MsgCond:CLS
0;Cap M ;Status:OK
1;Cap M ;Status:OK
DMS-100 Family RLCM Maintenance Manual XPM12 and up
minor
(continued)
Do
step 20
step 12
step 21
,P;MsgCond:OPN
,P;MsgCond:OPN
RLCM

Advertisement

Table of Contents
loading

Table of Contents