Nortel DMS-100 Series Maintenance Manual page 356

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

8-38 Card replacement procedures
NT2X10
RMM
(continued)
Replacing an NT2X10 card in an RMM
At your current location
1
At the MAP display
2
3
At the RMM shelf
4
297–8351–550 Standard 04.01 August 1999
Obtain a replacement card. Ensure that the replacement card has the same
product equipment code (PEC), including suffix, as the card to be removed.
Access the TTP level of the MAP and post the Line Test Unit to be replaced by
typing
>MAPCI;MTC;TRKS;TTP;POST T LTU ltu_no
and pressing the Enter key.
where
ltu_no
is the number of the faulty LTU
Example of a MAP response:
LAST CIRCUIT = 27
POST CKT IDLED
SHORT CLLI IS:
LTU
OK, CLLI POSTED
POST
DELQ
TTP 6–006
CKT TYPE
PM NO.
OG
RMM 0 0
Busy the trunks that are associated with the card to be replaced by typing
>BSY
and pressing the Enter key.
WARNING
Static electricity damage
Wear a wrist strap connected to the wrist strap
grounding point of a frame supervisory panel (FSP)
while handling circuit cards. This protects the cards
against damage caused by static electricity.
Replace the NT2X10 card using the procedure Replacing a card. When you
have completed the procedure, return to this point.
BUSY Q
DIG
COM LANG
STA S R DOT TE R
LTU
21