Nortel DMS-100 Series Maintenance Manual page 314

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

7-130 RLCM alarm clearing procedures
ESA
critical, minor
(continued)
5
6
7
8
297–8351–550 Standard 04.01 August 1999
To display the central-side (C-side) links and identify which RLCM associates
with the links, type
>TRNSL
and press the Enter key.
Example of a MAP response:
Link 0: RMM 0
Link 1: RMM 0
Link 2: ESA 0
Link 3: ESA 0
Record information for the ESA with a state that is not OK.
To identify the RLCM associated with the defective link and post the RLCM,
type
>POST LCM site frame lcm
and press the Enter key.
where
site
is the site name of the RLCM (alphanumeric)
frame
is the frame number of the RLCM (0 to 511)
lcm
is the number of the LCM (0 to 1)
To identify peripheral-side (P-side) links with defects associated with ESA, type
>TRNSL P
and press the Enter key.
Example of a MAP response:
Link 0: RMM 0
Link 1: RMM 0
Link 2: ESA 0
Link 3: ESA 0
Record information for the ESA link with a state that is not OK.
To busy the link that has defects, type
>BSY LINK link_no
and press the Enter key.
where
link_no
is the number of a P-side link identified in step 7
0;Cap MS;Status:OK
1;Cap MS;Status:OK
0;Cap M ;Status:SysB
1;Cap M ;Status:SysB
0;Cap MS;Status:OK
1;Cap MS;Status:OK
0;Cap M ;Status:SysB
1;Cap M ;Status:SysB
;MsgCond:OPN
;MsgCond:OPN
;MsgCond:CLS
;MsgCond:CLS
;MsgCond:OPN
;MsgCond:OPN
;MsgCond:CLS
;MsgCond:CLS