Esa Critical, Minor - Nortel DMS-100 Series Maintenance Manual

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

7-126
7-126
RLCM alarm clearing procedures
ESA
critical, minor
Alarm display
Indication
The alarm code ESA under the PM subsystem header indicates an ESA
alarm. The *C* indicates a critical ESA alarm. The absence of the *C*
under the ESA indicates a minor ESA alarm. The number (n) before ESA
indicates the number of ESA processors with the alarm condition.
Meaning
The n is the number of ESAs in the system busy (SysB) or in-service trouble
(ISTb) state.
Impact
The SysB condition directly affects service when the RLCM is in ESA.
There is no local backup. An interruption of service can occur if the RLCM
cannot contact the host office and the ESA processor is SysB.
The ISTb condition does not directly affect service. Investigate the trouble
condition to avoid a possible service interruption if the ESA condition
deteriorates.
Common procedures
There are no common procedures.
Action
This procedure contains a summary flowchart and a list of steps. Use the
flowchart to review this procedure. Follow the steps to perform the
procedure.
297–8351–550 Standard 04.01 August 1999
7-126
CM
MS
IOD
.
.
.
Net
PM
CCS
.
nESA
.
*C*
Lns
Trks
Ext
.
.
.
Appl
.