Replacing an NT6X52 card in an RLCM
At your current location
1
Obtain a replacement card. Ensure that the replacement card has the same
product equipment code (PEC), including suffix, as the card that is to be
removed.
2
If you were directed to this procedure from another maintenance procedure, go
to step 5; otherwise, continue with step 3.
At the MAP display
3
Access the PM level and post the LCM by typing
>MAPCI;MTC;PM;POST LCM site frame lcm
and pressing the Enter key.
where
site
is the site name of the RLCM
frame
is the frame number of the RLCE (0 to 511)
lcm
is the number of the LCM
4
Busy the LCM unit containing the faulty card by typing
>BSY UNIT lcm_unit
and pressing the Enter key.
where
lcm_unit
is the LCM unit to be busied (0 or 1)
At the RLCE
5
Replace the NT6X52 card using the procedure "Replacing a card". When the
card is replaced, return to this point.
6
If you were directed to this procedure from another maintenance procedure,
return now to the procedure that directed you here and continue as directed;
otherwise, continue with step 7.
DMS-100 Family RLCM Maintenance Manual XPM12 and up
Card replacement procedures 8-153
RLCM
NT6X52
(continued)