Replacing an NT6X75 card in an HIE
At your current location
1
Proceed only if you have been directed to this card replacement procedure from
a step in a maintenance procedure, are using the procedure for verifying or
accepting cards, or have been directed to this procedure by your maintenance
support group.
2
Obtain a replacement card. Ensure that the replacement card has the same
product equipment code (PEC), including suffix, as the card that is to be
removed.
3
If you were directed to this procedure from another maintenance procedure, go
to step 10; otherwise, continue with step 4.
At the MAP display
4
Post the LCM associated with the faulty NT6X75 card by typing
>MAPCI;MTC;PM;POST LCM site frame lcm
and pressing the Enter key.
where
site
is the name of the location of the RLCM
frame
is the number of the RLCE
lcm
is the number of the LCM in the RLCE
5
Translate the links to the P-side peripherals by typing
>TRNSL P
and pressing the Enter key.
6
Post the Emergency Stand-Alone (ESA) processor by typing
>POST ESA esa_no
and pressing the Enter key.
where
esa_no
is the number of the ESA processor identified in step 5.
DMS-100 Family RLCM Maintenance Manual XPM12 and up
Card replacement procedures 8-205
HIE
NT6X75
(continued)