Ntmx45 Hie - Nortel DMS-100 Series Maintenance Manual

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

8-244
8-244
Card replacement procedures
NTMX45
HIE
Application
Use this procedure to replace an NTMX45 in host interface equipment (HIE)
shelf.
PEC
NTMX45
If you cannot identify the PEC, suffix, and shelf or frame for the card you
want to replace, refer to the "Index" in this document. The index lists the
cards, shelves, and frames in this card replacement NTP.
Common procedures
This procedure does not refer to any common procedures.
Next level of maintenance
A problem can occur that requires the help of the local maintenance
personnel. Gather all important logs, reports, and system information (that
is, product type and current software load) for analysis. The related logs,
maintenance notes, and system information help make sure that the next
level of maintenance and support can find the problem. More detail about
logs appears in the Log Report Reference Manual.
Action
The flowchart that follows provides a summary of this procedure. Use the
instructions in the step-action procedure that follows the flowchart to replace
the card.
297–8351–550 Standard 04.01 August 1999
8-244
Suffixes
Name
AA
Emergency Stand-Alone (ESA) processor (EP)

Advertisement

Table of Contents
loading

Table of Contents