Nortel DMS-100 Series Maintenance Manual page 292

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

7-108 RLCM alarm clearing procedures
RLCM
minor
(continued)
26
27
28
29
297–8351–550 Standard 04.01 August 1999
To test the busied unit, type
>TST UNIT lcm_unit
and press the Enter key.
where
lcm_unit
is the LCM unit you must test (0 or 1)
If test
passes
fails, and the system produces a
card list
fails, and the system does not
produce a card list
To attempt to RTS the RLCM, type
>RTS UNIT lcm_unit
and press the Enter key.
where
lcm_unit
is the LCM unit to RTS (0 or 1)
If RTS
passes
fails
The card list identifies the cards that can become defective. Replace the cards
one at a time according to the following procedure.
If last card on list
was not replaced
was replaced
For additional help, contact the next level of support.
Do
step 27
step 28
step 29
Do
step 31
step 29
Do
step 30
step 29