Nortel DMS-100 Series Maintenance Manual page 322

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

8-4 Card replacement procedures
NT0X10
in RMM
(continued)
Replacing an NT0X10 card in an RMM
At your current location
1
At the MAP display
2
At the RMM shelf
3
4
297–8351–550 Standard 04.01 August 1999
Obtain a replacement card. Ensure that the replacement card has the same
product equipment code (PEC), including suffix, as the card to be removed.
Access the TTP level of the MAP and post the scan points on the card to be
replaced by tying
>MAPCI;MTC;TRKS;TTP;POST P RMM rmm_no ckt_no
and pressing the Enter key.
rmm_no
is the number of the RMM with the faulty NT0X10 card.
ckt_no
is the number of the first scan point (SC) of the seven SC
points on this card.
Example of a MAP display response:
LAST CIRCUIT = 14
POST CKT IDLED
SHORT CLLI IS:
OK, CLLI POSTED
POST
13
DELQ
TTP 6–006
CKT TYPE
PM NO.
OG TESTEQ
RMM 0 0
WARNING
Static electricity damage
Wear a wrist strap connected to the wrist strap
grounding point of a frame supervisory panel (FSP)
while handling circuit cards. This protects the cards
against damage caused by static electricity.
Replace the NT0X10 card using the procedure Replacing a card. When you
have completed the procedure, return to this point, otherwise go to step 6.
Send any faulty cards for repair according to local procedure.