Nortel DMS-100 Series Maintenance Manual page 370

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

8-52 Card replacement procedures
NT2X57
NT2X57
RMM
RMM
(continued)
(end)
At the MAP display
4
5
6
7
8
297–8351–550 Standard 04.01 August 1999
Repost to verify the signal distribution circuits on the card that was replaced by
typing
>POST P RMM rmm_no ckt_no
and pressing the Enter key.
where
rmm_no
is the number of the RMM shelf where the card was replaced
ckt_no
is the number of the first circuit where the NT2X57 card is physically
located.
Example of a MAP response:
LAST CIRCUIT = 14
POST CKT IDLED
SHORT CLLI IS:
OK, CLLI POSTED
POST
13
DELQ
TTP 6–006
CKT TYPE
PM NO.
OG TESTEQ RMM 0 0
Send any faulty cards for repair according to local procedure.
Record the following items in office records:
date the card was replaced
serial number of the card
symptoms that prompted replacement of the card
Go to step 8.
Obtain further assistance in replacing this card by contacting the personnel
responsible for higher level of support.
You have completed this procedure.