Nortel DMS-100 Series Maintenance Manual page 451

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

23
List the SLM file names into your user directory by typing
>LF volume_name
and pressing the Enter key.
where
volume_name is the name of the volume containing the PM load files,
obtained in step 20
24
Leave the disk utility by typing
>QUIT
and pressing the Enter key.
25
Reload the ESA processor by typing
>LOADPM
and pressing the Enter key.
If
load passed
load failed
26
Return the ESA processor to service by typing
>RTS
and pressing the Enter key.
If RTS
passed
failed
27
Send any faulty cards for repair according to local procedure.
28
Record the following items in office records:
date the card was replaced
serial number of the card
symptoms that prompted replacement of the card
Go to step 30.
DMS-100 Family RLCM Maintenance Manual XPM12 and up
Card replacement procedures 8-133
HIE
Do
step 26
step 29
Do
step 27
step 29
NT6X47
(continued)