Nortel DMS-100 Series Maintenance Manual page 284

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

7-100 RLCM alarm clearing procedures
RLCM
minor
(continued)
Clearing an RLCM minor alarm
At the MAP terminal
1
2
3
4
5
297–8351–550 Standard 04.01 August 1999
To silence the alarm, if required, type
>MAPCI;MTC;SIL
and press the Enter key.
To access the peripheral module (PM) level of the MAP display, type
>PM
and press the Enter key.
To identify the defective RLCM, type:
>DISP STATE ISTB LCM
and press the Enter key.
To post the RLCM with the alarm condition, type
>POST LCM site frame lcm
and press the Enter key.
where
site
is the site name of the RLCM (alphanumeric)
frame
is the frame number of the RLCM (0-511)
lcm
is the number of the LCM
To determine the fault indicators, type
>QUERYPM FLT
and press the Enter key.
If the fault
is ringing generator
is CBsy (C-side busy)
is PBsy (P-side busy)
is DRWR FLT (drawer fault)
is ISTb (In-service trouble)
Do
step 6
step 9
step 15
step 21
step 25

Advertisement

Table of Contents
loading

Table of Contents