Nortel DMS-100 Series Maintenance Manual page 459

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

16
Return to service the links busied in step 12 by typing
>RTS LINK link_no
and pressing the Enter key.
where
link_no
is one of two links associated with the replacement card
Note: Repeat this entry for the other link associated with the replacement
card.
If RTS
failed
passed
17
Determine if there are remaining links to clear.
If there are
remaining links to clear
no remaining links to clear
18
If you were directed to this procedure from another maintenance procedure,
return now to the procedure that directed you here and continue as directed;
otherwise, continue with step 19.
19
Determine if an LCM unit is manual busy.
If LCM unit
is ManB
is not ManB
DMS-100 Family RLCM Maintenance Manual XPM12 and up
Card replacement procedures 8-141
HIE
Do
step 24
step17
Do
step 12
step18
Do
step 20
step 22
NT6X50