Nortel DMS-100 Series Maintenance Manual page 177

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

6
To post the host peripheral, one of a line group controller (LGC), line trunk
controller (LTC) , or remote cluster controller (RCC), type
>POST pm pm_no
and press the Enter key.
where
pm
pm_no
7
To display the P-side links, type
>TRNSL P
and press the Enter key.
Example of a MAP response:
REM1 00 0
0; Cap MS; Status:SysB;MsgCond:CLS
Link 6: LCM REM1 00 0
Record information for the links that have a status other than OK.
8
To busy the link that has defects, type
>BSY LINK link_no
and press the Enter key.
where
link_no
is the number of a peripheral-side (P-side) link with defects
identified in step 7
9
To test the busied link, type
>TST LINK link_no
and press the Enter key.
where
link_no
is the number of a P-side link that has defects busied in step 8
If test
passes
fails
DMS-100 Family RLCM Maintenance Manual XPM12 and up
RLCM recovery procedure
is the name of the PM (LGC, LTC, or RCC)
is the number of the PM
1; Cap MS; Status:SysB;MsgCond:CLS
Do
step 10
step 27
Recovery procedures 6-7
(continued)

Advertisement

Table of Contents
loading

Table of Contents