Nortel DMS-100 Series Maintenance Manual page 205

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Clearing an RLCM RG critical alarm with a ringing generator
Enter this procedure from the PM system level alarm clearing
procedures step that identifies an LCM associated fault.
At the MAP terminal
1
To silence the alarm, type
>MAPCI;MTC;PM;SIL
and press the Enter key.
2
To identify the RLCM that has faults, type
>DISP STATE ISTB LCM
and press the Enter key.
Example of a MAP response:
ISTb
REM1 00 0
3
To post the ISTb RLCM identified in step 3, type
>POST LCM site frame_no lcm_no
and press the Enter key.
where
site
is the name of the site of the LCM location
frame_no is the number of the frame (00 to 511)
lcm_no
is the number of the LCM (0 or 1) in the frame
Example of a MAP display:
SysB
ManB
PM
0
0
LCM
0
0
LCM
REM1
00 0 ISTb
Unit0:
SysB
Unit1:
ISTb
Drwr:
01
23
45
..
..
..
DMS-100 Family RLCM Maintenance Manual XPM12 and up
RLCM alarm clearing procedures 7-21
ATTENTION
OffL
CBsy
2
0
2
0
Links_OOS:
CSide
/RG: 0
/RG: 0
11
11
11
11
67
89
01
23
45
67
..
..
..
..
..
..
RLCM RG
critical
ISTb
InSv
1
12
1
9
0
PSide
0
11
RG:Pref 0 ISTb
89
Stby 1 ISTb
..
(continued)

Advertisement

Table of Contents
loading

Table of Contents