Nortel DMS-100 Series Maintenance Manual page 535

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Replacing an NTEX17 in an RLCM
At your current location
1
Proceed only if you were either directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure for verifying
or accepting cards, or were directed to this procedure by your maintenance
support group.
2
Obtain a replacement card. Make sure that the replacement card and the card
that you remove have the same product engineering code (PEC) and PEC
suffix.
At the xEMS workstation
3
Go to the submap of the LCM line drawer with the NTEX17 card that you will
replace.
4
Place the cursor on the XLC you want to busy and use the mouse to select
Maintenance : XLC –> MB
and press the Enter key.
At the MAP terminal
5
To access the LTP level of the MAP display, type
>MAPCI;MTC;LNS;LTP
and press the Enter key.
Example of a MAP display:
POST
DELQ
LCC PTY RNG .....LEN..........
Note: If you worked at the LTP level of the MAP display, a posted line can be
present. A posted line does not interfere with this maintenance procedure.
6
To post the line for the card to be replaced, type
>POST L site frame_no unit_no drawer_no slot_no
and press the Enter key.
where
site
is the PM location (alphanumeric)
frame_no
is the frame number (0 to 511)
unit_no
is the PM unit number (0 or 1)
drawer_no
is the line drawer number (0 to 19)
ckt_no
is the card slot number (0 to 31)
Example of a MAP display:
LCC PTY RNG .....LEN..........
1FR
REM1 01 0 01 01
DMS-100 Family RLCM Maintenance Manual XPM12 and up
Card replacement procedures 8-217
BUSYQ
PREFIX
DN
STA F S LTA
DN
STA F S LTA
621 1134 IDL
NTEX17
RLCM
(continued)
TE
RESULT
TE
RESULT

Advertisement

Table of Contents
loading

Table of Contents