Nortel DMS-100 Series Maintenance Manual page 51

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

RMM connection with host and LCA through LCC
DS30A
link pair
DS-1 links
Host
The RMM uses DMS-X protocol to communicate with the host, through the
LCC interface to the DS-1 links.
The RMM can accommodate a maximum of 14 maintenance and service
circuit cards. These cards vary in type and are selected to meet provisioning
requirements.
RMM shelf configuration
The RMM shelf has 20 slots. The two slots of the RMM (01, 02) at the top
left are assigned to the DS30 interface and control cards. Slots 17–18 and
20 on the far right of the shelf contain two types of power converters for the
RMM. The remainder of the shelf (slots 3–16) are assigned to service
circuit cards that must meet office engineering requirements. Figure
"Remote maintenance module shelf design" contains an example of card
selections for a normal RMM.
RMM control card
The RMM also requires the RMM control card (NT6X74AB), in slot 02.
The RMM control card acts as an interface between the line concentrating
array shelves and the test trunks, service circuits, and alarm circuits of the
RMM. The RMM control card processes DMS-X messages, trunk
messages, and pulse code modulation (PCM) data.
Power converters
Two types of power converters are required in the RMM shelf:
multi-output power converter (NT2X09)
5-V/40-A power converter (NT2X06)
DMS-100 Family RLCM Maintenance Manual XPM12 and up
RMM
Link
control
DS30A links
cards
Maintenance overview 1-35