Nortel DMS-100 Series Maintenance Manual page 507

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

At the MAP
6
Test the line card just replaced by typing
>DIAG
and pressing the Enter key.
If the DIAG
passed
failed
7
Return the line card to service by typing
>RTS
and pressing the Enter key.
If RTS
passed
failed
8
Send any faulty cards for repair according to local procedure.
9
Record the following items in office records:
date the card was replaced
serial number of the card
symptoms that prompted replacement of the card
Go to step 11.
10
Obtain further assistance in replacing this card by contacting the personnel
responsible for higher level of support.
11
You have successfully completed this procedure.
DMS-100 Family RLCM Maintenance Manual XPM12 and up
Card replacement procedures 8-189
RLCM
RLCM
Do
step 7
step 10
Do
step 8
step 10
NT6X71
NT6X71
(continued)
(end)

Advertisement

Table of Contents
loading

Table of Contents