7-114 RLCM alarm clearing procedures
PM LCM RG
minor
(continued)
Clearing a PM LCM RG minor alarm
At the MAP display
1
2
3
297–8351–550 Standard 04.01 August 1999
Enter this procedure from the PM system level alarm clearing
procedure step that identified an LCM ringing generator (RG)
associated fault.
To silence the alarm, if required, type
>MAPCI;MTC;PM;SIL
and press the Enter key.
To identify the LCM that has faults, type
>DISP STATE ISTB LCM
and press the Enter key.
Example of a MAP response:
ISTb: REM2 00 0
To post the ISTb LCM unit identified in step 2, type
>POST LCM lcm_site_name lcm_frame_no lcm_no
and press the Enter key.
where
lcm_site_name is the site name for the defective LCM
lcm_frame_no
is the number (00 to 511) of the LCM frame
lcm_no
is the number of the defective LCM
Example of a MAP response:
SysB
ManB
PM
1
0
LCM
0
0
LCM
REM2
00 0 ISTb
Unit0:
InsV
Unit1:
ISTb
Drwr:
01
23
45
..
..
..
ATTENTION
OffL
CBsy
2
0
2
0
Links_OOS:
CSide
/RG: 0
/RG: 0
11
11
11
11
67
89
01
23
45
67
..
..
..
..
..
..
ISTb
InSv
2
12
2
9
0
PSide
0
11 RG:Pref 0 InSv
89
Stby 1 ISTb
..