10
Observe the card listing shown on MAP display.
Example of a MAP response:
SITE FLR RPOS BAY_ID
Rem1 01
A00
Rem1 01
A00
11
Determine if the NT6X60 circuit card was replaced.
If the NT6X60 card has
been replaced
not been replaced
12
Return the LCM to service by typing
>RTS UNIT unit_no
and pressing the Enter key.
where
unit_no
is the number of the ManB LCM (0 or 1).
If
RTS PASSED
RTS FAILED
SHF DESCRIPTION SLOT EQPEC
RLCM 00
38
LCM:000
RLCM 00
04
LCM:000
DMS-100 Family RLCM Maintenance Manual XPM12 and up
RLCM alarm clearing procedures 7-59
major
:01
6X60
:04
6X51
Do
step 18
Go to step 17 to replace the
ringing generator
Do
step 13
step 18
RLCM RG
(continued)