Nortel DMS-100 Series Maintenance Manual page 336

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

8-18 Card replacement procedures
NT0X91
RLCE
(continued)
71
72
73
74
75
297–8351–550 Standard 04.01 August 1999
Return LCM unit 0 to service by typing
>RTS UNIT 0
and pressing the Enter key.
If unit 0
RTS passed
RTS failed
Post the RMM that is controlled by the alarm and control card you have just
replaced by typing
>POST RMM rmm_no
and pressing the Enter key.
where
rmm_no
is the number of the RMM to be posted, as recorded in step 5
Load the RMM by typing
>LOADPM
and pressing the Enter key.
Return the RMM to service by typing
>RTS
and pressing the Enter key.
If the rmm
RTS passed
RTS failed
Post the ESA processor that is controlled by the alarm and control card you
have just replaced by typing
>POST ESA esa_no
and pressing the Enter key.
where
esa_no
is the number of the ESA processor to be posted, as recorded in
step 5
Do
step 72
step 80
Do
step 75
step 80