Nortel DMS-100 Series Maintenance Manual page 191

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

7
To display the peripheral side (P-side) links, type
>TRNSL P
and press the Enter key.
Example of a MAP response:
Link 2: LCM REM1 00 0
Link 6: LCM REM1 00 0
Record information for the links that have a status other than OK.
8
To busy the link that has faults, type
>BSY LINK link_no
and press the Enter key.
where
link_no
is the number of a P-side link identified in step 7
9
To test the busied link, type
>TST LINK link_no
and press the Enter key.
where
link_no
is the number of the P-side link busied in step 8
If test
passes
fails
DMS-100 Family RLCM Maintenance Manual XPM12 and up
RLCM alarm clearing procedures 7-7
2; Cap MS; Status: SysB ;MsgCond: CLS
1; Cap MS; Status: SysB ;MsgCond: CLS
Do
step 10
step 30
RLCM
critical
(continued)

Advertisement

Table of Contents
loading

Table of Contents