Nortel DMS-100 Series Maintenance Manual page 348

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

8-30 Card replacement procedures
NT2X09
RMM
(continued)
Replacing an NT2X09 card in an RMM
At your current location
1
2
At the MAP display
3
4
5
297–8351–550 Standard 04.01 August 1999
Obtain a replacement card. Ensure that the replacement card has the same
product equipment code (PEC), including suffix, as the card to be removed.
If you were directed to this procedure from another maintenance procedure, go
to step 8; otherwise, continue with step 3.
Access the TTP level of the MAP and post the RMM that contains the card to
be replaced by typing
>MAPCI;MTC;TRKS;TTP;POST P RMM rmm_no
and pressing the Enter key.
where
rmm_no
is the number of the RMM shelf in which the card is to be replaced
Example of a MAP response:
LAST CIRCUIT = 27
POST CKT IDLED
SHORT CLLI IS:
OTDA00
OK, CLLI POSTED
POST
20
DELQ
TTP 6–006
CKT TYPE
PM NO.
OG
MF RMM 0 0
Check the status of the RMM.
If RMM status is
MB, PMB, RMB
other
Busy the trunks that are associated with the RMM to be busied by typing
>BSY ALL
and pressing the Enter key.
BUSY Q
COM LANG
OTWAON23DA00 2001
Do
step 8
step 5
DIG
STA S R DOT TE R
LO
P_IDL