Nortel DMS-100 Series Maintenance Manual page 501

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

12
Open the locking levers on the replacement card. Align the card with the slots
in the shelf and gently slide the card into the shelf.
13
Seat and lock the card.
1. Using your fingers or thumbs, push on the upper and lower edges of the
faceplate to ensure that the card is fully seated in the shelf.
2. Close the locking levers.
At the FSP
14
Turn ON the circuit breaker turned OFF in step 9.
15
Remove the wrist strap.
16
If you were directed to this procedure from the Alarm Clearing Procedures ,
return now to the alarm clearing procedure that directed you here. Otherwise,
continue with step 17.
At the MAP terminal
17
Return the LCM unit to service by typing
>RTS UNIT lcm_unit
and pressing the Enter key.
where
lcm_unit
is the number of the LCM unit (0 or 1) busied in step 8
If RTS
passed
failed
DMS-100 Family RLCM Maintenance Manual XPM12 and up
Card replacement procedures 8-183
HIE
Do
step 18
step 23
NT6X60
(continued)