8-266 Card replacement common procedures
Replacing a line card
RLCM
(continued)
5
6
297–8351–550 Standard 04.01 August 1999
c.
Squeeze the handles of the extractor together to grasp the card tightly.
d.
Hold the front cover of the line drawer to steady it with your left hand.
e.
Pull the extractor away from the drawer to unplug the card from its socket
on the drawer backplane.
f.
Continue pulling the card with the extractor until the card is clear of the
shroud.
g.
Insert the removed card into an ESD container and store according to local
procedures.
Verify that the product equipment code (PEC) on the nameplate of the removed
card and of the replacement card is the same.
Replace the faulty card using the following steps: