7-116 RLCM alarm clearing procedures
PM LCM RG
minor
(continued)
At the MAP terminal
7
8
9
297–8351–550 Standard 04.01 August 1999
To align RG activity to the good RG, if required, type
>SWRG UNIT unit_no
and press the Enter key.
where
unit_no
is the LCM unit (0 or 1) associated with the RG that has faults
Example of a MAP display:
LCM REM2 00 0 Unit 1 SWRG Passed
If the SWRG command
passes, and RG activity must be
switched for the other unit
passes, and RG activity is
acceptable for both PM units
fails
Repeat step 7 for the other LCM unit in this frame.
To manually busy the ISTb LCM unit, type
>BSY UNIT unit_no
and press the Enter key.
where
unit_no
is the number of the LCM unit (0 or 1) assigned to the RG that has
faults
Do
step 8
step 9
step 10