Nortel DMS-100 Series Maintenance Manual page 225

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

53
To post the RLCM, type
>POST LCM site frame lcm
and press the Enter key.
site
is the site name of the RLCM (alphanumeric)
frame
is the frame number of the RLCM (0-511)
lcm
is the number of the LCM
54
To test the LCM unit, type
>TST UNIT lcm_unit
and press the ENTER key.
where
lcm_unit
is the LCM unit busied in step 23
If TST
passes
fails
55
To return to service the LCM unit, type
>RTS UNIT lcm_unit
and press the ENTER key.
where
lcm_unit
is the LCM unit tested in step 54
56
For additional help to clear this alarm, contact the next level of support.
57
This procedure is complete. If the system displays other alarms, refer to the
correct clearing alarm procedures for the indicated alarms.
DMS-100 Family RLCM Maintenance Manual XPM12 and up
RLCM alarm clearing procedures 7-41
RLCM talk battery alarm
RLCM talk battery alarm
critical
critical
Do
step 55
step 56
(continued)
(end)