Align RG activity to the preferred RG by typing
>SWRG UNIT unit_no
and pressing the Enter key.
where
unit_no
is the LCM unit (0 or 1) assigned to the new RG
Example of a MAP display:
LCM REM1 14 0 InSv Links
Unit 0: InSv
Unit 1: InSv
Drwr:
01
23
45
..
..
––
Note: Repeat this step until both units of the LCM are on the preferred RG.
If the SWRG command
passed
failed
Go to the appropriate procedure in the Card Replacement Procedures . When
17
you have finished with the card replacement procedures, go to step 12 of this
procedure.
18
Obtain further assistance in clearing this alarm by contacting the personnel
responsible for higher level support.
19
You have successfully completed this procedure. If there are other alarms
displayed, reference the appropriate alarm clearing procedures for the indicated
alarms.
OOS: Cside 0 Pside 0
/RG:1
/RG:1
11
11
11
67
89
01
23
45
––
––
––
..
––
DMS-100 Family RLCM Maintenance Manual XPM12 and up
RLCM alarm clearing procedures 7-61
major
11
11
RG: Pref 1 InSv
67
89
Stby 0 InSv
..
..
Do
step 19
step 18
RLCM RG
RLCM RG
major
(continued)
(end)