7-60 RLCM alarm clearing procedures
RLCM RG
major
(continued)
13
14
15
297–8351–550 Standard 04.01 August 1999
Align RG activity to the new RG by typing
>SWRG UNIT unit_no
and pressing the Enter key.
where
unit_no
is the LCM unit (0 or 1) associated with the new RG
Example of a MAP display:
LCM REM1 14 1 Unit 1 SWRG Passed
If the SWRG command
passed, and RG activity must be
switched for the other LCM unit
passed, and RG activity is
acceptable for both LCM units
failed
Repeat step 13 for the other LCM unit in this frame.
Test the new RG by typing
>TST UNIT unit_no
and pressing the Enter key.
where
unit_no
is the number of the LCM unit (0 or 1).
Example of a MAP response:
LCM REM1 14 1 Unit 1
LCM REM1 14 1 Unit 1
Note: Repeat this step for the other LCM unit.
If TST
passed
failed
Do
step 14
step 15
step 18
InSvce Tests Initiated
Tst Passed
Do
step 16
step 18