Nortel DMS-100 Series Maintenance Manual page 406

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

8-88 Card replacement procedures
NT6X17
RLCM
(continued)
Replacing an NT6X17 card in an RLCM
At your current location
1
At the MAP terminal
2
3
4
5
297–8351–550 Standard 04.01 August 1999
Obtain a replacement card. Ensure that the replacement card has the same
product equipment code (PEC), including suffix, as the card that is to be
removed.
Access the LTP level of the MAP terminal and post the line associated with the
card to be replaced by typing
>MAPCI;MTC;LNS;LTP;POST L site lcm lsg ckt
and pressing the Enter key.
where
site is the name of the site where the RLCM is located
lcm is the number of the RLCM with the faulty card
lsg
is the number of the line subgroup with the faulty card
ckt
is the number of the circuit associated with the faulty card
Example of a MAP response:
LCC PTY RNG .....LEN.........
1FR
REM1 00 0 03 03
Check the status of the posted line.
If the line status is
manual busy (ManB)
not ManB
Busy the line by typing
>BSY
and pressing the Enter key.
Go to the procedure "Replacing a line card". When you have completed the
procedure, return to this point.
DN
STA F S LTA TE RESULT
7213355 MB
Do
step 5
step 4