8-34 Card replacement procedures
NT2X09
RMM
(continued)
25
26
27
28
29
30
31
297–8351–550 Standard 04.01 August 1999
Go to step 30.
From office records, determine and note the number of the system load module
(SLM) disk and the number of the volume that contains the PM load files.
Access the disk utility level of the MAP by typing
>DISKUT
and pressing the Enter key.
List the SLM file names into your user directory by typing
>LV CM;LF Volume_name
and pressing the Enter key.
where
Volume_name is the name of the volume containing the PM load files,
obtained in step 26.
Leave the disk utility by typing
>QUIT
and pressing the Enter key.
Reload the RMM by typing
>LOADPM
and pressing the Enter key.
If
load failed
load passed
Return the RMM to service by typing
>RTS
and pressing the Enter key.
If RTS
passed
failed
Do
step 36
step 31
Do
step 32
step 36