Nortel DMS-100 Series Maintenance Manual page 290

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

7-106 RLCM alarm clearing procedures
RLCM
minor
(continued)
22
23
297–8351–550 Standard 04.01 August 1999
To busy the two line subgroups that associate with the drawer that has defects,
type
>BSY DRWR lsg
and press the Enter key
where
lsg
is the number of the line subgroups that associate with the drawer
that has defects
Example of a MAP response:
LCM
REM1 00 0
Please confirm ("YES" or "NO"):
>YES
and press the Enter key
Repeat this step for the other line subgroup the associates with the drawerthat
has defects.
To test the two line subgroups that associate with the drawer that has defects,
type
>TST DRWR lsg
and press the Enter key.
where
lsg
is the number of one of the line subgroups that associate with the
drawer that has defects.
Note: Repeat this step for the other line subgroup that associates with the
drawer that has defects.
If test
passes
fails, and the system produces a
card list
fails, and the system does not
produce a card list
Drwr 2 will be taken out of service
Do
step 24
step 28
step 29