Nortel DMS-100 Series Maintenance Manual page 558

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

8-240 Card replacement procedures
NTEX54
RLCM
(continued)
At the MAP terminal
23
24
25
297–8351–550 Standard 04.01 August 1999
Note: Fuses are coded for position. The colored square on the face of the
fuse identifies the top edge.
a.
Insert the +5V fuse.
b.
Insert the +15V fuse.
c.
Insert the –48V fuse.
A maintenance flag (Mtce) can appear. This flag indicates that system-initiated
maintenance tasks are in progress. To stop the system-initiated maintenance
tasks, type
>ABTK
and press the Enter key.
To return the logical drawer to service, type
>RTS DRWR drwr_no
and press the Enter key.
where
drwr_no
is the logical drawer number (0 to 19)
Example of a MAP response:
OSvce Tests Initiated
LCM REM1 00 0
Drwr 0 Tst Passed
LCM REM1 00 0
Drwr 0 Rts Passed
If the RTS command
passed, and you must return the
other logical drawer to service
passed, and the other logical drawer
is in service
failed
Repeat step 24 for the other logical drawer in the pair.
Do
step 25
step 26
step 39