7-22 RLCM alarm clearing procedures
RLCM RG
critical
(continued)
4
At the RLCM site
5
6
297–8351–550 Standard 04.01 August 1999
To check for fault indicators, type
>QUERYPM FLT
and press the Enter key.
Example of a MAP display:
LCM
UNIT 0
Inservice troubles Exist:
Ringing Generator Failure:Ring Generator ANI/COIN Fault
LCM
UNIT 1
Inservice Troubles Exist:
Ringing Generator Failure:Ring Generator in Excess load
If QUERYPM
indicates RG failure
does not indicate RG failure
Perform a visual inspection of the ringing generator. Check to see if the LED is
lit.
If the LED
is lit
is not lit
To power up the ringing generator, move the power switch to the ON position.
(The LED must go off.) These switches follow:
RG 0
circuit breaker CB2
RG 1
circuit breaker CB3
If power
is restored
is not restored
Do
step 6
step 5
Do
step 6
step 7
Do
step 19
step 7