Nortel DMS-100 Series Maintenance Manual page 361

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

At the MAP display
5
Test the new NT2X11 card by typing
>TST
If TST
passed
failed
and pressing the Enter key.
6
Return to service the circuits busied in step 3 by typing
>RTS
and pressing the Enter key.
If RTS
passed
failed
7
Send any faulty cards for repair according to local procedure.
8
Record the following items in office records:
date the card was replaced
serial number of the card
symptoms that prompted replacement of the card
Go to step 10.
9
Obtain further assistance in replacing this card by contacting the personnel
responsible for higher level of support.
10
You have completed this procedure.
DMS-100 Family RLCM Maintenance Manual XPM12 and up
Card replacement procedures 8-43
RMM
RMM
Do
step 6
step 9
Do
step 7
step 9
NT2X11
NT2X11
(continued)
(end)