7-122 RLCM alarm clearing procedures
RMM
minor
(continued)
Clearing an RMM minor alarm
At the MAP terminal
1
2
3
4
5
297–8351–550 Standard 04.01 August 1999
To silence the alarm, type
>MAPCI;MTC;PM;SIL
and press the Enter key.
To identify the defective RMM, type
>DISP STATE ISTB RMM
and press the Enter key.
Example of a MAP response
ISTb
RMM: 2
To post the in-service trouble (ISTB) RMM in step 2, type
>POST RMM rmm_no
and press the Enter key.
where
rmm_no
is the number of the defective RMM
To perform an in-service test on the defective RMM, type
>TST
and press the Enter key.
If test
passes
fails because C-side links are not
available
fails and a card list appears
fails and a card list does not
appear
To identify the RLCM with links busied by the system (SYSB), type
>TRNSL C
and press the Enter key.
Do
step 17
step 5
step 14
step 17