16
To attempt to reload the ESA processor, type
>LOADPM
and press the Enter key.
If load
is successful
is not successful
17
The card list identifies cards that can have defects. Replace the cards one at a
time in the order listed.
If all cards on the list
are replaced
are not replaced
18
To return to service the ESA processor, type
>RTS
and press the Enter key.
If return to service
is successful
fails because of loading error
fails because of CBsy condition
other than listed here
19
Go to the card replacement procedure Card Replacement Procedures for the
next card on the card list. When you finish the card replacement procedure, go
to step15 of this procedure.
20
To obtain additional help to clear this alarm, contact the next level support.
21
The procedure is complete. If additional alarms display, go to the appropriate
how procedure on how to clear alarms.
RLCM alarm clearing procedures 7-133
DMS-100 Family RLCM Maintenance Manual XPM12 and up
critical, minor
critical, minor
(continued)
Do
step 15
step 20
Do
step 20
step 19
Do
step 21
step 16
step 4
step 20
ESA
ESA
(end)