Nortel DMS-100 Series Maintenance Manual page 178

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

6-8 Recovery procedures
RLCM recovery procedure
10
11
12
297–8351–550 Standard 04.01 August 1999
(continued)
To return the busied link to service, type
>RTS LINK link_no
and press the Enter key.
where
link_no
is the number of P-side links with defects tested in step 9
If test
passes and no other links are SysB
passes but other links are SysB
fails
To identify the RLCM with defects, type
>DISP STATE SYSB LCM
and press the Enter key.
If response
shows SysB LCMs are not present
shows SysB LCMs
To post the RLCM with the alarm condition, type
>POST LCM site frame lcm
and press the Enter key.
where
site
is the site name of the RLCM (alphanumeric)
frame
is the frame number of the RLCM (0–511)
lcm
is the number of the LCM (0 or 1)
Do
step 11
step 8
step 27
Do
step 32
step 12

Advertisement

Table of Contents
loading

Table of Contents