8-22 Card replacement procedures
NT2X06
RMM
(continued)
Replacing an NT2X06 card in an RMM
At your current location
1
2
At the MAP terminal
3
4
5
297–8351–550 Standard 04.01 August 1999
Obtain a replacement card. Ensure that the replacement card has the same
product equipment code (PEC), including suffix, as the card to be removed.
If you were directed to this procedure from the Alarm Clearing Procedures , go
to step 6. Otherwise, continue with step 3.
Access the peripheral module (PM) level of the MAP display by typing
>MAPCI;MTC;PM
and pressing the Enter key.
Post the RMM by typing
>POST RMM rmm_no
and pressing the Enter key.
where
rmm_no
is the number of the RMM shelf where the card is to be replaced
Example of a MAP response:
SysB
PM
0
RMM
1
RMM
0
SysB
Busy the RMM by typing
>BSY
and pressing the Enter key.
ManB
Offl
2
2
0
1
CBsy
ISTb
0
7
0
0
InSv
21
6