To display the peripheral side (P-side) link information, type:
> TRNSL P
and press the Enter key.
Example of a MAP response:
Link 2: ILCM REM1 00 0
Link 6: ILCM REM1 00 0
7
Record the numbers of the links with status not correct.
Use the following diagram to determine the PCM-30 interface card(s) that
correspond to the links that step 6 identifies as defective.
Note: Each NT6X27 card has two ports. For example, the defective link 6
appears in step 6. This link connects to port 1 as indicated, Port 1 corresponds
to the NT6X27 in slot 20.
Port numbers
Slot numbers
8
Determine the slot location of the defective card.
If defective card
is in slot 19 or 20 of the HIE
is in slot 21 of the HIE
DMS-100 Family RLCM Maintenance Manual XPM12 and up
Card replacement procedures 8-111
NT6X27 port numbers
0;Cap MS;Status:OK
1;Cap MS;Status:SysB ;MsgCond: CLS
6
6
6
X
X
X
2
2
2
7
7
7
0
1
4
2
3
5
19
20
21
Do
step 9
step 12
NT6X27
in HIE
(continued)
;MsgCond: OPN