Nortel DMS-100 Series Maintenance Manual page 365

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

At the RMM shelf
4
WARNING
Static electricity damage
Wear a wrist strap connected to the wrist strap
grounding point of a frame supervisory panel (FSP)
while handling circuit cards. This protects the cards
against damage caused by static electricity.
Replace the NT2X48 card using the procedure Replacing a card . When you
have completed the procedure, return to this point.
At the MAP display
5
Test all of the digitone receivers on the new NT2X48 card by typing
>TST
6
Continue testing through all four digitone circuits on the card by typing
>NEXT
If TST
passed
failed
7
Repost all four ESADGTR circuits by typing
>POST P RMM rmm_no ckt_no to ckt_no
and pressing the Enter key.
where
ckt_no
is the number of the first and last circuits on the NT2X48 card.
Example of a MAP response:
LAST CIRCUIT = 27
POST CKT IDLED
SHORT CLLI IS:
OK, CLLI POSTED
POST
3
DELQ
TTP 6–006
CKT TYPE
PM NO.
OG
RMM
0 0
DMS-100 Family RLCM Maintenance Manual XPM12 and up
Card replacement procedures 8-47
1125
BUSY Q
COM LANG
ESAGDTR 11
RMM
(continued)
Do
step 7
step 11
DIG
STA S R DOT TE R
IDL
NT2X48

Advertisement