Nortel DMS-100 Series Maintenance Manual page 218

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

7-34 RLCM alarm clearing procedures
RLCM talk battery alarm
critical
(continued)
21
22
At the MAP terminal
23
297–8351–550 Standard 04.01 August 1999
Does the FSP use NTI repeaters?
FSP
uses NTI repeaters
does not use NTI repeaters
To reset circuit breaker CB8 or CB9, move the switch to the ON/OFF and back
to the ON position in quick sequence. The LED must go OFF.
If circuit breaker
trips again
remains ON, LED goes off
To busy the LCM unit, type
>BSY UNIT lcm_unit
and press the Enter key.
where
lcm_unit
is the LCM unit to busy
If
CB8 is the circuit breaker tripped
CB9 is the circuit breaker tripped
Do
step 22
step 32
Do
step 23
step 57
Busy
unit 0
unit 1