Nortel DMS-100 Series Maintenance Manual page 219

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

24
To identify the C-side peripheral, type
>TRNSL C
and press the Enter key.
Example of a MAP response:
Link
0: LTC 0
Link
1: LTC 0
Link
2: LTC 0
Link
3: LTC 0
25
To post the peripheral, type
>POST pm_type pm_no
and press the Enter key.
where
pm_type
pm_no
26
To diplay the P-side links, type
>TRNSL P
and press the Enter key.
Example of a MAP response:
Link 0: LCM REM1 00 0
Link 1: LCM REM1 00 0
Record information for the links to busy.
27
To busy the line
>BSY LINK link_no
and press the Enter key.
where
link_no
is the number of a P-side link that interfaces the RLCM
Note: Perform this step for each link that interfaces the RLCM unit
busied in step 23.
Host XPM type and number
0;Cap
MS;Status:OK
1;Cap
MS;Status:OK
3;Cap
s;Status:OK
4;Cap
S;Status:OK
is the name of the host XPM (LGC, LTC, or RCC)
is the number of the host XPM (0 to 255)
2;Cap MS;Status:OK;
1;Cap MS;Status:OK;
DMS-100 Family RLCM Maintenance Manual XPM12 and up
RLCM alarm clearing procedures 7-35
RLCM talk battery alarm
critical
;MsgCon:CLS
;MsgCon:CLS
MsgCond: CLS
MsgCond: CLS
(continued)

Advertisement

Table of Contents
loading

Table of Contents