Nortel DMS-100 Series Maintenance Manual page 431

Remote line concentrating module
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Change DIP switch settings on the new replacement card to match the
defecitve card to be removed.
14
Use the procedure Replacing a card to replace the NT6X27 card . When you
replace the card, return to this step.
At the MAP display
15
To test the busy links in step 12, type:
>TST LINK link_no
and press the Enter key.
where
link_no
is one of two links associated with the replacement card
Note: Repeat this step for the other link associated with the replacement
card.
If test
fails
passes
16
To Return to service (RTS) the links busied in step 12, type:
>RTS LINK link_no
and press the Enter key.
where
link_no
is one of two links for the replacement card
Note: Repeat this entry for the other link associated with the replacement
card.
If RTS
fails
passes
DMS-100 Family RLCM Maintenance Manual XPM12 and up
Card replacement procedures 8-113
in HIE
Do
step 23
step16
Do
step 23
step17
NT6X27
(continued)

Advertisement

Table of Contents
loading

Table of Contents