1-66 Maintenance overview
Faults that occur on a BIC drawer can affect call processing. The unit that is
in service and controls that drawer does not determine if the faults affect call
processing. Because the full in-service tests use the DCC, determine if the
fault is not in the DCC, when takeover must occur. If takeover occurs as a
result of a reported drawer fault, the DCC is at fault even though the LCM
fails the BIC tests.
In the takeover mode, the inactive unit DCC cannot access drawers for call
processing. The inactive unit DCC can access drawers for testing. The
active LCM unit continues to have access to drawers through the DCC of the
LCM.
Valid drawer faults do not take an LCM unit out-of-service. The status of
the unit is ISTb. The ISTb reason is Self Test or Diag Fail. The test that
297–8351–550 Standard 04.01 August 1999
RINGING_FAIL
BIC_INHIBIT_TEST
RTM_CM_TEST
BIC_LA_TEST
RTTS_CM_TEST
BIC_LOOPAROUND
SANITY_TIMEOUT_FAIL
BIC_SCAN_TEST
SET_MSG_LOOPAROUND
DCC_LA_TEST
SUBCYCLE_LENGTH_FAIL
DS1_LOOPAROUND
SUBCYCLE_ORDER_FAIL
IUC_LA_TEST
TIMING_TEST
LC_COM_TEST
WRITE_PROTECT_FAIL
LCC_FAIL
ZERO_CROSSING_INT_FAST_FAIL
LCC_LOOPAROUND
ZERO_CROSSING_INT_SLOW_FAIL
MEMORY_TEST