25
To attempt to reload the RLCM, type
>LOADPM PM CC
and press the Enter key.
If load
is successful
is not successful in one unit
is not successful
26
To attempt again to return the RLCM to service, type
>RTS PM
and press the Enter key.
If return to service for either unit
is successful
is not successful
27
Contact maintenance personnel for additional instructions when you clear this
defect.
28
Go to the Card Replacement Procedures to replace the first or next card on the
card list. Notify outside plant personnel of the card to change. Go to step 25
when you replace the card.
29
To attempt to load the LCM unit, type
>LOADPM UNIT lcm_unit
and press the Enter key.
where
lcm_unit
is the LCM unit (0 or 1) that failed to load in step 25
If load
is successful
is not successful
RLCM recovery procedure
DMS-100 Family RLCM Maintenance Manual XPM12 and up
Recovery procedures 6-13
Do
step 26
step 29
step 27
Do
step 32
step 27
Do
step 30
step 27
(continued)