18
Determine if the RLCM has the ESA timer set for manual recovery from ESA.
To access table OFCENG, type
>TABLE OFCENG
and press the Enter key.
19
To check the RLCM exit time, type
>POS RLCM_XPMESAEXIT
and press the Enter key.
Example of a MAP response:
PARMNAME
–––––––––––––––
RLCM_XPMESAEXIT
If PARMVAL is
set to zero
greater than zero
20
Before you manually restore the RLCM from ESA, determine if links to the
RLCM are steady. To find the link numbers for this RLCM , type
>TRNSL C
and press the Enter key.
Example of a MAP response:
Link
0:
LTC 1
Link
1:
LTC 1
Link
2:
LTC 1
Link
3:
LTC 1
21
To access the CARRIER level of the MAP terminal, type
>TRKS;CARRIER
and press the Enter key.
PARMVAL
Do
step 20
Allow the system to recover the RLCM. Go to step 30.
0;Cap MS;Status:OK
2;Cap MS;Status:OK
3;Cap
4;Cap
DMS-100 Family RLCM Maintenance Manual XPM12 and up
RLCM alarm clearing procedures 7-11
critical
3
S;Status:OK
S;Status:OK
RLCM
(continued)
;MsgCon:OPN
;MsgCon:OPN

Advertisement